CI-6600 Oxygen O2 Gas Analyzer

CI-6600 Oxygen O2 Gas Analyzer

Short Description:

 


Product Detail

Technical Specifications

Applications

Product Tags

CI-6600 Oxygen O2 Gas Analyzer

 

It has the characteristics of intelligencegood stability, high reliability and long calibrationcycle.

The latest touch button technology is adopted to prolong the service life of keys. Measure the relative pressure inside the air path and check whether the air path is

blocked.aIOMenu lock switch:to prevent the impact of wrong operation on the analyzer;’Alarm function:When the oxygen concentration deviates from the alarm value or runsincorrectly,the alarm value can be set freely within the full range.Communication function:RS232/RS485 two-way communication,can communicate directlywith computer or other digital communication equipment.
Sensor principle: Frequency conversion ion flow

Measure range: 0~25.00% 0

Accuracy:

0.01~99.9ppm5ppm

100~999.9ppm 3%FS

1000~9999ppm 3%FS

1.00%~25.00%+3% of the measured value

Repeatability:0.01~99.9ppm+2.5ppm

100~999.9ppm 1.5%FS

1000~9999 ppm +1.5%FS

1.00%~25.00% 1.5%ofthe measured value

Stability:

0.01~99.9 ppm 2.5ppm/7d

100~999.9ppm 1.5%FS/7d

1000~9999ppm+1.5%FS/7d

1.00%~25.00% 1.5% of the measured value/7dResponse time:Tgo<20s(after full preheating)

Relay contact

point capacity:24VDC,0.2A

Power supply:85~264VAC,50/60Hz

Calibration cycle: recommended once a year

Communication:RS232(standard)/RS485(optional)

Environment

temperatureSample

10~50°CEnvironment Humidity:<80%RH

gas pressure:atmospheric conditionst10%(Gas outlet should be atmospheric conditions)Analyzer size:

CI-PC128:

LxWxH=300mmx270mmx132mm

CI-PC128-1:

LxWxH=300mmx242.5mmx125mm

Install hole size: CI-PC128:

LxW=235.5mmx129mm

CI-PC128-1:

LxW=200mmx124mm

 


  • Previous:
  • Next:

  • Measure Range:       0-10/100/1000ppm,0-1%O2

    Accuracy:            <=±5% in the range of 0-10ppm;s±3% in the range of 0-100ppm;s±2% in the range of 0-100pm;

    Display Resolution:    0.01ppm

    Response Time:       T90<=65s(0-1000ppm)

    Measure Medium:     H2, He, hydrocarbons, inert gas, mixed gas & acidic gases

    Stability:            Zero drift <=±1% of FS/7d; Span drift <=±1% of FS/7d

    Sample Gas Flow:     800-1000ml/min

    Repeatability:        <=±2.5% F.S(0-10ppm);<=±1.5% F.S(0-100ppm);<=±1% F.S(0-1000ppm);

    Sample Gas Pressure:  35KPa-210KPa

    RecoveringTime:      Reducing concentration in the air to 1ppm in 60mins

    Sensor Life:          24months at 25℃ and 1 atm.

    Sensor Principle:      Electrochemical Sensor

    Warranty:           12 months analyzer; 12 months sensor

    Weight:             4.5kg

    Appearance dimension: 255mm×250mm×160mm(L×W×H)

    It can be used to measure the trace oxygen concentration in the fields of nitrogen separation from air, chemical process, magnetic materials such as high temperature sintering furnace gas protection, the electronics industry protective gas, glass & building materials industries, various mixed gases, etc.