  1. The power indicator light is on, and the left suction, equal-pressure and right suction indicator light circulates to indicate the oxygen production process.

     

  2. When the left suction indicator light is on, the pressure of the left adsorption tower rises to the maximum gradually from the equilibrium pressure, at the same time, the pressure of the right adsorption tower falls to zero gradually from the equilibrium pressure. When the indicator light is on, the pressure of the left and right adsorption towers will gradually reach the balance of one liter and one drop.

 

  1. When the right suction indicator light is on, the pressure of the right adsorption tower gradually rises to the highest from the equilibrium pressure, at the same time, the pressure of the left adsorption tower gradually drops to zero.

     

  2. The oxygen outlet pressure is indicated as the normal gas pressure. The pressure will fluctuate slightly during use, but the change is very small.

 

  1. The flow indicator of the flow meter should be basically stable and not fluctuate too much. The indicating value of the flow meter should not be greater than the rated gas production capacity of the oxygen production equipment.

     

  2. The indicating value of oxygen meter should not be less than the rated purity of oxygen production equipment. There may be a little fluctuation, but it should not fluctuate too much.